AtaGenix

Anti 2019-nCoV Nsp13 polyclonal antibody

  • 1
ATP238
-
+
Spot
Inquiry
  • Product Details
  • References
  • How to order
  • Instructions
Summaryicon
Product name
Anti 2019-nCoV Nsp13 polyclonal antibody
Catalog#
ATP238
description
Produced in rabbits immunized with purified,Recombinant SARS-CoV-2 NSP13 protein
Accession #
P0DTD1
Alternative names
Helicase,Hel,Non-structural protein 13,Replicase polyprotein 1ab
Stability &Storage
Use a manual defrost freezer and avoid repeated freeze thaw cycles.
Store at 2 to 8 °C for one week .
Store at -20 to -83 °C for twelve months from the date of receipt.
Spcificity
Recognizes SARS-CoV-2 NSP13 protein
Isotype
IgG
Host
Rabbit
Clonality
Polyclonal
Conjugation
Unconjugated
Species reactivity
Severe acute respiratory syndrome coronavirus 2 (2019-nCoV) (SARS-CoV-2)
Tested applications
Elisa
Immunogen
Recombinant SARS-CoV-2 NSP13(Ala5325-Gln5925)
Backgroundicon
Multi-functional protein with a zinc-binding domain in N-terminus displaying RNA and DNA duplex-unwinding activities with 5' to 3' polarity. Activity of helicase is dependent on magnesium.
Product performanceicon
Form
Liquid
Buffer
PBS, pH7.4, containing 0.05% proclin300, 50% glycerol.
Concentration
0.95 mg/ml
MW
65kDa
Applicationicon
Dilution Range
Elisa:1:4000~1:8000
Tested Pictureicon
    Noteicon
    For research use only.
    PMID: 32500504,PMID: 22615777

    Guarantee and Disclaimer:

    After receiving the product, if finds that the product is mismatched, damaged or missing components, please keep the original package and submit the objection to the company by mail within seven working days. Failure to file an objection within the time limit is considered qualified.

    When the buyer keeps the product, it should be kept in accordance with the storage conditions shown in the product label and the manual. If the product quality is caused by improper storage, it will not be guaranteed.

    When the buyer tests the product, they should be submitted by the beginning of use when found the quality issue, rather than when the product was used or used up, in order to prepare our products for recycling and confirm the quality of the products. If it is the quality problem, our company is responsible for exchange or return. In the event of a claim, our company will compensate the discretion within the scope of the product price limit and will not accept any part of the value of the product itself. Since the date of receipt, the product has not been reflected for more than three months and should not be returned.

    The products provided by our company are for research use only and should not be used for clinical diagnosis or treatment. If a unit or individual changes the use of our products without authorization, we will not bear any responsibility.