AtaGenix

CD163 mouse monoclonal antibody

  • 1
  • 2
ATDA00012
-
+
Spot
Inquiry
  • Product overview
  • Product performance
  • Dilution range
  • Product background
  • How to order
  • Instructions
product nameicon
CD163 mouse monoclonal antibody
catalog No.icon
ATDA00012
Categoryicon
Primary antibody
Hosticon
Mouse
Species specificityicon
This antibody detects endogenous levels of human CD163. Heat-induced epitope retrieval (HIER) TRIS-EDTA of pH8.0 was highly recommended as antigen repair method in paraffin section
Tested applicationsicon
IHC-p
Clonalityicon
Monoclonal
Immunogenicon
Synthesized peptide derived from human CD163.
Alternative Namesicon
Scavenger receptor cysteine-rich type 1 protein M130(Hemoglobin scavenger receptor) ,CD antigen CD163,cleaved into:Soluble CD163 (sCD163),M130
Uniprot IDicon
Q86VB7
Formicon
Liquid
Buffericon
Liquid in PBS containing 50% glycerol, 0.5% BSA and 0.02% sodium azide.
Storageicon
Stored at -20℃.Avoid repeated freeze-thaw cycles.
Concentrationicon
1 mg/ml
Isotypeicon
IgG1,Kappa
IHC-p:1:100-1:500
CD163 molecule(CD163) Homo sapiens The protein encoded by this gene is a member of the scavenger receptor cysteine-rich (SRCR) superfamily,and is exclusively expressed in monocytes and macrophages.It functions as an acute phase-regulated receptor involved in the clearance and endocytosis of hemoglobin/haptoglobin complexes by macrophages,and may thereby protect tissues from free hemoglobin-mediated oxidative damage.This protein may also function as an innate immune sensor for bacteria and inducer of local inflammation.Alternatively spliced transcript variants encoding different isoforms have been described for this gene.

Guarantee and Disclaimer:

After receiving the product, if finds that the product is mismatched, damaged or missing components, please keep the original package and submit the objection to the company by mail within seven working days. Failure to file an objection within the time limit is considered qualified.

When the buyer keeps the product, it should be kept in accordance with the storage conditions shown in the product label and the manual. If the product quality is caused by improper storage, it will not be guaranteed.

When the buyer tests the product, they should be submitted by the beginning of use when found the quality issue, rather than when the product was used or used up, in order to prepare our products for recycling and confirm the quality of the products. If it is the quality problem, our company is responsible for exchange or return. In the event of a claim, our company will compensate the discretion within the scope of the product price limit and will not accept any part of the value of the product itself. Since the date of receipt, the product has not been reflected for more than three months and should not be returned.

The products provided by our company are for research use only and should not be used for clinical diagnosis or treatment. If a unit or individual changes the use of our products without authorization, we will not bear any responsibility.